KegLand

JoinTech G40 Glycol Chiller - Compressor Chiller with 4 Pumps, 4 Digital Controllers & 30 L Reservoir on Castors

Price: €1.099,00

Pallet delivery

Delivery in the Netherlands and Belgium is calculated at checkout. Shipping to another country? We quote pallet delivery personally. Send us your postcode and you'll usually have a price within one working day.

Pairs well with

Four vessels, four schedules, one compressor. The JoinTech G40 is the chiller for the brewer who has outgrown one fermenter: four built-in pumps, each with its own digital controller and its own 3 m probe, running off a 30 L glycol reservoir. Ferment a saison warm in tank one, hold an IPA at 18 °C in two, cold crash a lager in three and keep a bright tank or kegmenter at serving temperature in four — all at once, all from a unit on castors that you roll into the corner.

Cooling is compressor-based (R600a, 400 W rated at 22 °C ambient), which for this job is 3–6× more energy-efficient than thermoelectric and keeps working when the room is warm. The reservoir has its own STC-1000 controller; the four pump controllers sit on the front. It is rated for four well-insulated 60 L FermZilla All Rounders or four 58 L kegmenters with Temp Twisters, and it also pulls wort down to pitching temperature once you've brought it under 50 °C with tap water. The 1/2" JoinTech ports have automatic shut-off valves, so swapping a hose from one tank to another doesn't put glycol on the floor.

Not included: hoses, hose-end connectors and glycol. Each vessel needs two female JoinTech couplings (13 mm barb), 13 mm ID insulated hose and clamps; the 30 L reservoir takes about 6 L of propylene glycol at a 20% mix — two 5 kg jugs. The heater connection on the controllers is unused out of the box; a heating element must be fitted by an electrician.

Delivery in 3–5 business days to addresses in the Netherlands and Belgium.

Key features

  • Four independent pumps, 600 l/h and 5 m head each, with four digital controllers
  • Four 3 m temperature probes included — one per vessel
  • 30 L glycol reservoir with STC-1000 reservoir controller
  • Compressor cooling (R600a), 400 W at 22 °C ambient
  • 1/2" male JoinTech fittings with automatic shut-off — spill-free disconnects
  • Castor wheels; EU plug; heater connection for an optional element

Usage

  • Fill with a 20% propylene glycol mix, prime all four pumps and set the reservoir 2–3 °C below your coldest target
  • One pump per vessel: insulated 13 mm hose to the coil or jacket, probe taped to the vessel wall under the insulation
  • Insulate everything you connect — four bare steel tanks in a warm room will out-run any chiller
  • Cold crash one tank while the others ferment: set that controller to 1–2 °C, leave the rest alone
  • Chilling wort: pre-chill to under 50 °C with tap water first, then let the glycol finish the job
  • Keep the vents clear and the unit upright; check the glycol level monthly

Quick facts

  • Cooling power: 400 W at 22 °C (compressor, R600a)
  • Pumps: 4 × 600 l/h, 5 m max head, each with digital controller
  • Reservoir: 30 L, STC-1000 controller
  • Probes: 4 × 3 m, included
  • Fittings: 1/2" male JoinTech, auto shut-off (female couplings sold separately)
  • Packed: 52 × 50 × 78 cm, 34.5 kg
  • Delivery: 3–5 business days, NL & BE only

Related products